Difference between revisions of "FIF Translator Version 4 - September, 2007"

From ATTWiki
Jump to: navigation, search
(Data Included In Conversion)
Line 14: Line 14:
  
 
<table cellpadding="15" width = 550>
 
<table cellpadding="15" width = 550>
 +
 +
 +
<tr valign="top">
 +
<td bgcolor="#abbad1" width=150>
 +
<font size=4><b>XYZ DATA</b></font>
 +
----<br>
 +
</td>
 +
 +
<td bgcolor="#e3e4f5">
 +
*NEW - Properly skip REFERENCE points in the XYZ data.  (Reference points are not intersection or end points.  They are not used to define the shape of the tube.)
 +
*NEW - Retain XYZ data as it exists in the FIF file.  No longer attempt a recalc from YBC to XYZ.  This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.
 +
</td>
 +
</tr>
 +
 +
 +
<tr valign="top">
 +
<td bgcolor="#abbad1" width=150>
 +
<font size=4><b>YBC DATA</b></font>
 +
----<br>
 +
</td>
 +
 +
<td bgcolor="#e3e4f5">
 +
*NEW - Retain YBC data as it exists in the FIF file.  No longer attempt a recalc from XYZ to YBC.  This allows measuring centers to retain original YBC bender setup data during conversion.
 +
</td>
 +
</tr>
 +
  
  
Line 31: Line 57:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW FUNCTION DATA</b></font>
+
<font size=4><b>FUNCTION DATA</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
  
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
*Y Function - Bits 12345678
+
New Conversion of all YBC FUNCTION Bits (12345678)
*B Function - Bits 12345678
+
</td>
*C Function - Bits 12345678
+
</tr>
<br>
+
*Y, B, C axes Stop Bits
+
*C axis Last Bit
+
  
 +
 +
<tr valign="top">
 +
<td bgcolor="#abbad1" width=150>
 +
<font size=4><b>SPECIAL FUNCTION DATA</b></font>
 +
----<br>
 +
</td>
 +
 +
<td bgcolor="#e3e4f5">
 +
New Conversion of all YBC FUNCTION STOP and LAST Bits
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 48: Line 80:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW PROCESS DATA</b></font>
+
<font size=4><b>PROCESS DATA</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
  
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
 +
NEW VALUES CONVERTED:
 
*Default Radius
 
*Default Radius
 
*End A Diameter
 
*End A Diameter
 
*End B Diameter
 
*End B Diameter
 +
 +
(Diameter was already converted)
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 61: Line 96:
 
<tr valign="top">
 
<tr valign="top">
 
<td bgcolor="#abbad1" width=150>
 
<td bgcolor="#abbad1" width=150>
<font size=4><b>NEW TOOL DATA</b></font>
+
<font size=4><b>TOOL DATA</b></font>
 
----<br>
 
----<br>
 
</td>
 
</td>
Line 67: Line 102:
 
<td bgcolor="#e3e4f5">
 
<td bgcolor="#e3e4f5">
 
Handles Up to 9 Radius Levels for:
 
Handles Up to 9 Radius Levels for:
*Radius
+
*NEW - Radius
*Fixed Springback
+
*NEW - Fixed Springback
*Proportional Springback
+
*NEW - Proportional Springback
*Clamp Length
+
*NEW - Clamp Length
*Clearance Feed
+
*NEW - Clearance Feed
*Clearance Angle
+
*NEW - Clearance Angle
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 111: Line 146:
 
</tr>
 
</tr>
 
</table>
 
</table>
 
  
 
=Automatic Conversion of Units=
 
=Automatic Conversion of Units=
  
 
The following values can be automatically converted to Inches or Millimeters during conversion:
 
The following values can be automatically converted to Inches or Millimeters during conversion:

Revision as of 03:43, 14 September 2007

Contents


Enhancements Information

  • Now ALL data found in an FIF file is converted to the Supravision format.
  • Distance data can be automatically converted to the other unit (Millimeters to Inches, or Inches to Millimeters).
  • Improved error handling.
  • This version retains both the XYZ and YBC data intact. There is no forced conversion in one direction or another between the two data types.


Data Included In Conversion

XYZ DATA



  • NEW - Properly skip REFERENCE points in the XYZ data. (Reference points are not intersection or end points. They are not used to define the shape of the tube.)
  • NEW - Retain XYZ data as it exists in the FIF file. No longer attempt a recalc from YBC to XYZ. This allows measuring centers to be sure to retain original XYZ MASTER data during conversion.

YBC DATA



  • NEW - Retain YBC data as it exists in the FIF file. No longer attempt a recalc from XYZ to YBC. This allows measuring centers to retain original YBC bender setup data during conversion.

VELOCITY DATA



NEW Conversion of YBC axes speeds: 1 - 8

FUNCTION DATA



New Conversion of all YBC FUNCTION Bits (12345678)

SPECIAL FUNCTION DATA



New Conversion of all YBC FUNCTION STOP and LAST Bits

PROCESS DATA



NEW VALUES CONVERTED:

  • Default Radius
  • End A Diameter
  • End B Diameter

(Diameter was already converted)

TOOL DATA



Handles Up to 9 Radius Levels for:

  • NEW - Radius
  • NEW - Fixed Springback
  • NEW - Proportional Springback
  • NEW - Clamp Length
  • NEW - Clearance Feed
  • NEW - Clearance Angle

NEW MACHINE DATA from EL Setup Data



  • Ymin
  • Interference Zone 1
  • Interference Zone 2
  • Load Position
  • Load Offset
  • Y Position Tolerance
  • Pressure Die Open Code
  • Boost Delay

NEW MACHINE DATA from EL Extended Setup Data



  • Any number of EXTENDED setup values are automatically converted
  • Older benders (like Velog, EL-2000, and Premier) contain 40 extended setup values
  • Newer benders can contain more
  • FIF Translator takes in up to 99 extended values for conversion.

Automatic Conversion of Units

The following values can be automatically converted to Inches or Millimeters during conversion: