Eaton Leonard Lightspeed Communications Setup

From ATTWiki
Revision as of 16:00, 17 June 2014 by Mcone (Talk | contribs)

Jump to: navigation, search

This document outlines the basic communications setup for a Lightspeed control.

EL Lightspeed.jpg



SVNET Communications Setup

STEP 1: System Menu

Change to the Systems menu. If you are not running the operator station as an administrator, then press SECURITY and enter the administrator code. (The default code is "123".)

Press the DEVICE CONFIG button.

EL Lightspeed SystemMode.png


STEP 2: Device Config / Machine Menu

In DEVICE CONFIG, enter the MACHINE menu.

  • NAME: The NAME has no effect on the protocol. However, you can give the setup a name here.

  • PROTOCOL: Select the SupraGauge protocol.

  • BENDER NUMBER: Set the bender to an integer number that identifies it. This is very important if you have multiple benders that share the same network location for transfer of data files.

  • CHECKBOX OPTIONS: Select any of the checkbox options that you want to enable.

    • LOG: To log activity as it occurs

    • METRIC: To make all linear data communicate in Millimeters rather than the default Inches

    • PRESET CLR: To ignore any incoming Centerline Radius data.

  • NETWORK PATH: Set the Network Path to a location on the network that allows read/write access. This is the path where all machines and measuring centers will drop and pickup command files using the Supravision Network protocol.

EL Lightspeed DeviceConfig Machine.png
EL Lightspeed DeviceConfig Machine MeasuringCenterSetup.png