Operatorstation model.jpg



CHANGES to CNC PROCESSLIST BUILDER

Check.jpg New - Ensure Clamp is Home after PD Retract Timer Before Post Bend Jog (Logic Change)

The Pressure Die Retract Timer COMDEF command can open the pressure die a small distance and simultaneously send the clamp die home. The command is considered complete when the pressure die has arrived at its timed destination. The next step is often for a Post Bend Jog (which is a bend die clearance move for non split-die benders).

Because our operator station systems are becoming so fast, it is easily possible for the Feed axis to start the Post Bend Jog without the clamp die arriving completely home. This is a typical process list where this problem can occur:

PressureDieReturnWithTimer_SendClampAndBoostHome = tim2:200, cto:6000

AllBoostReturn = cto:6000

FeedPositive = pos0:50.80000000, vel0:900.00000000, ump0:1, cto:60000


The PressureDieReturnWithTimer_SendClampAndBoostHome command sends the pressure due out a timed duration then issues a constant energized clamp and PD boost outputs to home. In this case, the process is so fast that the FeedPositive command may be start moving before the clamp die returns home. (This is more likely to happen when the PD Boost slide is already home because PD Boost is switched off.)

To solve the problem, the PLBuilder inserts the ClampHomeComplete command in the logic like this:

PressureDieReturnWithTimer_SendClampAndBoostHome = tim2:200, cto:6000

ClampHomeComplete = cto:6000

AllBoostReturn = cto:6000

FeedPositive = pos0:50.80000000, vel0:900.00000000, ump0:1, cto:60000