The '''PressureDieReturnWithTimer_SendClampAndBoostHome''' command sends the pressure due out a timed duration, and issues a constant clamp and boost (pressure die assist) return or home command.  In this case, the
+
The '''PressureDieReturnWithTimer_SendClampAndBoostHome''' command sends the pressure due out a timed duration then issues a constant clamp and boost (pressure die assist) return or home command.  In this case, the
 
<br>
 
<br>
 
This is an example of the new process list with the ClampHomeComplete command added to the logic:
 
This is an example of the new process list with the ClampHomeComplete command added to the logic:

Revision as of 22:10, 26 February 2008

Cncbender logo.jpg

Operatorstation model.jpg



CHANGES to CNC PROCESSLIST BUILDER

Check.jpg New Insert of ClampHomeComplete with PD Retract Timer

The Pressure Die Retract Timer COMDEF command can open the pressure die a small distance and simultaneously send the clamp die home. The command is considered complete when the pressure die has arrived at its timed destination. The next step is often for a Post Bend Jog (which is a bend die clearance move for non split-die benders).

Because our operator station systems are becoming so fast, it is easily possible for the Feed axis to start the Post Bend Jog without the clamp die arriving completely home. This is a typical process list where this problem can occur:

PressureDieReturnWithTimer_SendClampAndBoostHome = tim2:200, cto:6000

AllBoostReturn = cto:6000

FeedPositive = pos0:50.80000000, vel0:900.00000000, ump0:1, cto:60000


The PressureDieReturnWithTimer_SendClampAndBoostHome command sends the pressure due out a timed duration then issues a constant clamp and boost (pressure die assist) return or home command. In this case, the
This is an example of the new process list with the ClampHomeComplete command added to the logic:

PressureDieReturnWithTimer_SendClampAndBoostHome = tim2:200, cto:6000

ClampHomeComplete = cto:6000

AllBoostReturn = cto:6000

FeedPositive = pos0:50.80000000, vel0:900.00000000, ump0:1, cto:60000