Difference between revisions of "CNC Bender v10-20070928"

From ATTWiki
Jump to: navigation, search
(Update to File SAVE Window)
Line 67: Line 67:
  
 
<br><br>
 
<br><br>
 +
 +
=CHANGES to CNC PROCESSOR=
 +
 +
CNC Processor is the program that directly controls the bender actuators.
 +
 +
===High Speed Timer Upgrade===
 +
 +
The CNC Processor timer, in older versions, would generate an error in CNC Processor after Windows had been running continuously for about 25 days.  This has been repaired so that the timer will allow Windows to run continuously for >> days without reboot.
 +
 +
<br><br>
 +
 +
 +
  
 
=How to UPGRADE=
 
=How to UPGRADE=

Revision as of 01:26, 29 September 2007

CNC Bender User Interface for ProControl

Cncbender logo.jpg

Contents


CHANGES to CNC BENDER

Automatic FEED Torque Limit When Outside of Range

Now CNC Bender software uses the FEED torque limiting values programmed into the Low Level menu to ensure that any torque levels outside the range are automatically changed to be within valid range. This change occurs inside the Process List Builder.

This will protect the carriage against very low or high torque values in the CNC Bender Process List.



Update to File Load User Window

CNC Bender's FILE LOAD menu is reworked significantly based on customer input.

  • There is no more multiple path selection with Alias names. This was very confusing for operators, so it has been removed.
  • The menu now expands to fill the screen of an operator station.
  • The menu has a new file display window that will show the information inside the selected file. This allows you to instantly view the data inside that file before loading it into memory.
  • The selection of a new and custom path is much simpler.
  • The custom path is considered temporary. It is only used in the current session for that window.
  • The custom path feature requires a password for use.

Cncbender fileload.jpg



Update to File SAVE Window

CNC Bender's FILE SAVE menu is simplified. This is no more multiple path selection with Alias names.

Cncbender filesave.jpg





Update to File DELETE Window

CNC Bender's DELETE SAVE menu is simplified. This is no more multiple path selection with Alias names.

Cncbender filedelete.jpg




File System Setup Change

The FILE PATH SETUP has been changed significantly to make the interface simpler.

  • There is a new FILE tab in the LOW LEVEL menu. Since the low level menu is protected with a password, only authorized users can gain access to where parts are found and stored on the disk or network.
  • There is now a single grid that shows seven possible paths for user files like parts, tools, runlists, Supravision parts, etc.
  • The path information in this setup grid is used by the main user interface when accessing different types of files.
  • The paths are persistent; They are saved within the configuration file.
  • Change any of the paths for any of the file types by touching that path.
  • Quickly reset the default file path location pressing the "Reset..." button.


Cncbender lowlevel pathlocation selection.jpg




CHANGES to CNC PROCESSOR

CNC Processor is the program that directly controls the bender actuators.

High Speed Timer Upgrade

The CNC Processor timer, in older versions, would generate an error in CNC Processor after Windows had been running continuously for about 25 days. This has been repaired so that the timer will allow Windows to run continuously for >> days without reboot.





How to UPGRADE

If your operator station contains one of the versions listed below, then they can be upgraded through simple self-installation: