Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer.<br>
 
Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer.<br>
  
==Version 5==
+
==Version 5.1==
 
Release Date: October 6, 2014<br><br>
 
Release Date: October 6, 2014<br><br>
 
* Back to [[Benderlink for MiiC Version Updates]] web page<br><br>
 
* Back to [[Benderlink for MiiC Version Updates]] web page<br><br>
Line 24: Line 24:
 
<td  width=300 >
 
<td  width=300 >
 
[[image:vtube-step_logo.jpg|300px]]<br><br>
 
[[image:vtube-step_logo.jpg|300px]]<br><br>
The included VTube-STEP is upgraded to version 1.95.  This allows you to import solid models into MiiC benders. See [[VTube-STEP]]<br><br>
+
The included VTube-STEP is upgraded to version 1.95.  This allows you to import solid models into MiiC benders.<br><br>
 +
* See [[VTube-STEP Revisions]] for details on new versions.<br><br>
 
</td>
 
</td>
 
<td>
 
<td>
Line 33: Line 34:
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]] FIX: Calculation of Bender Data==
+
==[[image:Check.jpg|25px]] FIX: Rotation Calculation in MiiC Edit Part Data==
 
<table>
 
<table>
 
<tr>
 
<tr>
 
<td  width=300>
 
<td  width=300>
The Convert to PRB feature is repaired.  Previous versions moved the rotations down a row in the PRB data.<br><br>
+
Previous versions calculated the correct rotations - but inserted them in the wrong rows in the PRB data.<br><br>
 +
This has been repaired.<br><br>
 +
[[image:Benderlink_MiiC_5.1_ConvertToPRB_Closeup.png]]<br><br>
 
[[image:Benderlink_MiiC_5.1_ConvertToPRB.png|500px]]
 
[[image:Benderlink_MiiC_5.1_ConvertToPRB.png|500px]]
 
</td>
 
</td>
Line 44: Line 47:
 
<br><br>
 
<br><br>
  
== [[image:Check.jpg|25px]] NEW: Eaton Leonard Laservision Communication==
+
==[[image:Check.jpg|25px]] ENHANCED - Improved Error Handling and Dialogs ==
  
<table>
+
<table cellpadding=20>
<tr>
+
<tr valign=top>
<td width=300>
+
<td width=300>
The Eaton Leonard Laservision communication protocol was added.<br>
+
The error dialogs and logging are new in this version.<br><br>
 +
The ability to capture errors in Benderlink has been improved with this new logging system.<br><br>
 +
Error logs can now be reported directly to the Advanced Tubular bug logging database through the internet.<br><br>
 +
We've also included a new log viewer for viewing the error logs stored in the Benderlink configuration folder.<br><br>
 +
[[image:eurekalog_benderlink_miic_5.1.png|300px]]
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vector_tube_data_center.jpg|200px]]
+
[[image:benderlink_miic_5.1_eurekalog_dialog1.png|400px]]<br><br>
 +
[[image:benderlink_miic_5.1_eurekalog_dialog2.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
<br><br>
 
 
==[[image:Check.jpg|25px]] NEW: Faster Communications with Logic Improvements==
 
<table>
 
<tr>
 
<td  width=300>
 
The communications logic was redesigned.  Communication is significantly faster than older versions.  Also a logic problem was found and repaired with some floating point numbers.<br><br>
 
[[image:benderlink_miic_v5_communications_banner.png|400px]]
 
</td>
 
</tr>
 
</table>
 
<br><br>
 
 
  
 
==[[image:Check.jpg|25px]] Other Changes==
 
==[[image:Check.jpg|25px]] Other Changes==
Line 75: Line 70:
 
<tr>
 
<tr>
 
<td width=400>
 
<td width=400>
*New: Ping serial device servers before attempting to open COM ports at the MiiC benders<br><br>
+
*PRB Menu: The reverse calculate from PRB to XYZ feature is removedIt is a feature that has no-known value to customers.<br><br>
*Fixed:  Floating point conversion issues during data send are repaired.<br><br>
+
*New: MOXA serial device drivers are added since we now supply MOXA as our first choice of serial device servers.<br><br>
*Improved: Benderlink Network Menu is improved and easier to use<br><br>
+
*Improved: Moved the storage of configuration data to My Documents\Benderlink for MiiC to comply with Microsoft rules about where to put configuration files.<br><br>
+
*New: Press Enter in the PRB grid to move to the next cell down.<br><br>
+
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 17:04, 5 June 2017

Blinkmiic logo.jpg Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer.

Version 5.1

Release Date: October 6, 2014

Benderlink miic v5.png



Check.jpg UPDATE: VTube-STEP 1.95

Vtube-step logo.jpg

The included VTube-STEP is upgraded to version 1.95. This allows you to import solid models into MiiC benders.

Vtube-step-1.89 screenimage.png



Check.jpg FIX: Rotation Calculation in MiiC Edit Part Data

Previous versions calculated the correct rotations - but inserted them in the wrong rows in the PRB data.

This has been repaired.

Benderlink MiiC 5.1 ConvertToPRB Closeup.png

Benderlink MiiC 5.1 ConvertToPRB.png



Check.jpg ENHANCED - Improved Error Handling and Dialogs

The error dialogs and logging are new in this version.

The ability to capture errors in Benderlink has been improved with this new logging system.

Error logs can now be reported directly to the Advanced Tubular bug logging database through the internet.

We've also included a new log viewer for viewing the error logs stored in the Benderlink configuration folder.

Eurekalog benderlink miic 5.1.png

Benderlink miic 5.1 eurekalog dialog1.png

Benderlink miic 5.1 eurekalog dialog2.png

Check.jpg Other Changes

  • PRB Menu: The reverse calculate from PRB to XYZ feature is removed. It is a feature that has no-known value to customers.

  • New: MOXA serial device drivers are added since we now supply MOXA as our first choice of serial device servers.