Difference between revisions of "Benderlink for KEINS"

From ATTWiki
Jump to: navigation, search
 
(TECHNICAL INFORMATION)
 
(68 intermediate revisions by one user not shown)
Line 1: Line 1:
[[image:Blink_chiyoda_keins_5_82_main1.jpg|right|350px]]
+
<table>
 +
<tr cellpadding=10>
 +
<td width=300 valign=top>
 +
[[image:blink_keinschiyoda_orangefire.jpg|300px]]<br>
 +
Connect measuring centers with [[Chiyoda]] and [[KEINS]] benders and store all bender data on your network using Benderlink.
  
This software is designed to communicate with Chiyoda and KEINS benders.
+
* Back to [[Benderlink]]
 +
* Back to [http://www.advancedtubular.com/Benderlink_Chiyoda_Keins.htm the Main Benderlink for Chiyoda/KEINS] web page
  
__TOC__
+
</td>
 +
<td width=300>
 +
[[image:blink_keinschiyoda_screens_6.1_recall.jpg|300px]]
 +
</td>
 +
</tr>
 +
</table>
 +
__NOTOC__
 +
<br>
  
 +
[[image:keinsbender.png|400px]]
 +
 +
== REVISIONS and UPGRADES LIST ==
 +
 +
* See [[Benderlink for Chiyoda/KEINS Revisions]] page<br><br>
 +
 +
== TECHNICAL INFORMATION ==
 +
 +
* See [[How Benderlink for Chiyoda/KEINS Handles Data for Multi-User Login]]
 +
* See [[Configuration Data Storage for Benderlink for Chiyoda/KEINS]]
 +
* [[Data Conversion Rules for Benderlink for Chiyoda/KEINS]]
 +
* See [https://www.advancedtubular.com/blink_keinschiyoda/20181207%20Direct%20connection%20test%20of%20Benderlink%20with%20Chiyoda%20with%20Keyspan.htm Instructions for Direct Communications Test]
 +
<br><br>
 +
 +
== SOFTWARE MAINTENANCE ==
 +
 +
See the [[Benderlink for ChiyodaKEINS Software Maintenance Plan]]<br><br>
  
 
== MAIN FEATURES ==
 
== MAIN FEATURES ==
  
1 - It allows for intelligent bi-directional communications with measuring centers.
+
{| border="1" cellpadding="10" cellspacing="0" align="none" width=450
 +
|-
 +
! style="background:#b3b0c8;" | Feature
 +
! colspan="2" style="background:#acbcce;" | Description
 +
|-
 +
| Communicate
 +
| Benderlink can communicate and manage files for up to 99 benders
 +
|-
 +
| Edit bender data in Windows
 +
| It allows for true [[DNC]] offline programming.  This means that you can control every setup parameter from Benderlink <br>
 +
<br>
 +
<font size=0>(Note: All operator accessible parameters are programmable.  The low level passworded machine parameters that control the personality of the bender are not programmable by Benderlink.)</font>
 +
|-
 +
| Network Part Storage
 +
| It allows customers to use a PC disk / network to store all [[Chiyoda]] / [[KEINS]] parts off the control.  (Bypassing the floppy drive.)
 +
|-
 +
| Corrections Loops
 +
| Allow measuring centers to correct the bender setup
 +
|}
 +
 
 +
<br><br>
 +
 
 +
==OFFLINE License==
 +
 
 +
The Benderlink offline license allows engineers to program Benderlink from a location that are off-site or at a remote location.  The only difference between the OFFLINE license and the FULL license is that the OFFLINE version of the software will not communicate with benders.  Typically offline license is used to save the data files to a shared network location.  The full version of Benderlink that is connected to the bender can load the files created and saved with the offline version of Benderlink.
 +
 
 +
 
 +
<br><br>
 +
 
 +
==PDF DataSheets==
 +
 
 +
 
 +
<table cellpadding="15" width = 650>
 +
<tr valign="top">
 +
<td bgcolor="#abbad1" width = 200>
 +
[[image:Blinkkeins_datasheet.jpg|200px]]
 +
</td>
 +
<td bgcolor="#e3e4f5">
 +
[http://www.advancedtubular.com/blink_kb/blink_keins_datasheet.pdf Download a Datasheet] for Benderlink for
 +
KEINS
 +
<br><br>
 +
[http://www.advancedtubular.com/blink_kb/blinkmodule_keins_datasheet.pdf Download a Datasheet] for Benderlink Ethernet Module for KEINS
 +
 
 +
</td>
 +
</tr>
 +
 
 +
 
 +
<tr valign="top">
 +
<td bgcolor="#abbad1" width = 200>
 +
[[image:blink_keinschiyoda_capplication1.jpg|200px]]
 +
</td>
 +
<td bgcolor="#e3e4f5">
 +
[http://www.advancedtubular.com/blink_keinschiyoda/capplication1.pdf Download a customer success story]
 +
</td>
 +
</tr>
 +
 
  
2 - It allows for offline programming.
+
</table>
  
3 - It allows customers to use a PC disk / network to store all Chiyoda / KEINS parts off the control.  (Bypassing the floppy drive.)
 
  
  
== REVISIONS ==
+
==OTHER PAGES==
  
June 1, 2007 -
+
*[[Benderlink]] Page
[[Revision: Benderlink for Chiyoda/Keins 5.82]]
+
  
February 12, 2007 -
+
*[[Benderlink for Chiyoda FAQ]]
[[Revision: Benderlink for Chiyoda/Keins 5.72]]
+
  
February 4, 2007 -
+
*About [[Chiyoda]] - See this page for control version information.
[[Revision: Benderlink for Chiyoda/Keins 5.71b]]
+

Latest revision as of 02:00, 8 December 2018

Blink keinschiyoda orangefire.jpg
Connect measuring centers with Chiyoda and KEINS benders and store all bender data on your network using Benderlink.

Blink keinschiyoda screens 6.1 recall.jpg


Keinsbender.png

REVISIONS and UPGRADES LIST

TECHNICAL INFORMATION



SOFTWARE MAINTENANCE

See the Benderlink for ChiyodaKEINS Software Maintenance Plan

MAIN FEATURES

Feature Description
Communicate Benderlink can communicate and manage files for up to 99 benders
Edit bender data in Windows It allows for true DNC offline programming. This means that you can control every setup parameter from Benderlink


(Note: All operator accessible parameters are programmable. The low level passworded machine parameters that control the personality of the bender are not programmable by Benderlink.)

Network Part Storage It allows customers to use a PC disk / network to store all Chiyoda / KEINS parts off the control. (Bypassing the floppy drive.)
Corrections Loops Allow measuring centers to correct the bender setup



OFFLINE License

The Benderlink offline license allows engineers to program Benderlink from a location that are off-site or at a remote location. The only difference between the OFFLINE license and the FULL license is that the OFFLINE version of the software will not communicate with benders. Typically offline license is used to save the data files to a shared network location. The full version of Benderlink that is connected to the bender can load the files created and saved with the offline version of Benderlink.




PDF DataSheets

Blinkkeins datasheet.jpg

Download a Datasheet for Benderlink for KEINS

Download a Datasheet for Benderlink Ethernet Module for KEINS

Blink keinschiyoda capplication1.jpg

Download a customer success story


OTHER PAGES

  • About Chiyoda - See this page for control version information.