# <b>NEW DATA:</b> To send NEW data, be sure that the FRB data in CNC Bender is cleared.  There should be all zeros in all six fields of the first row.  There should only be one row.<br><br>[[image:Cncblink_frb_beforeblink_new.jpg|350px]]<br><br>
 
# <b>NEW DATA:</b> To send NEW data, be sure that the FRB data in CNC Bender is cleared.  There should be all zeros in all six fields of the first row.  There should only be one row.<br><br>[[image:Cncblink_frb_beforeblink_new.jpg|350px]]<br><br>
 
#<b>CORRECTION DATA</b> If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields. If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen.  The existing part will have been corrected with the wrong data.<br><br>
 
#<b>CORRECTION DATA</b> If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields. If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen.  The existing part will have been corrected with the wrong data.<br><br>
 +
 +
 +
= How To Determine if Benderlink for CNC Bender Is Active =
 +
 +
The status of Benderlink is displayed in the lower right corner of the CNC Bender screen:
 +
 +
[[image:Cncblink_status.jpg]]
 +
 +
If the LED flashes GREEN, then Benderlink is active.<br><br>
 +
If the LED flashes YELLOW, then Benderlink is active but busy.<br><br>
 +
If the LED is solid RED, then Benderlink is NOT active.<br><br>

Revision as of 19:30, 25 February 2008

Cncblink logo.jpg




How CNC Bender and Benderlink Interact

CNC Bender software communicates with Benderlink when Benderlink either requests data or sends data. These are the simple rules for using Benderlink in CNC Bender:


  1. MANUAL MODE ONLY:CNC Bender must be in MANUAL mode, or CNC Bender will not allow for the transfer.

  2. NEW DATA: To send NEW data, be sure that the FRB data in CNC Bender is cleared. There should be all zeros in all six fields of the first row. There should only be one row.

    Cncblink frb beforeblink new.jpg

  3. CORRECTION DATA If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields. If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen. The existing part will have been corrected with the wrong data.


How To Determine if Benderlink for CNC Bender Is Active

The status of Benderlink is displayed in the lower right corner of the CNC Bender screen:

Cncblink status.jpg

If the LED flashes GREEN, then Benderlink is active.

If the LED flashes YELLOW, then Benderlink is active but busy.

If the LED is solid RED, then Benderlink is NOT active.