VTube Communications With Transfluid Benders
|
This page describes the use of the VTube-LASER to Transfluid bender corrections. |
Back to VTube-LASER
Configuring VTube-STEP and VTube-LASER for Communications with Transfluid tProject
As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER.
You can set this protocol in the Benderlink setup grid in System Options.
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for Transfluid Supravision Network Protocol
|
Configuring Transfluid tProject for Communications with VTube-LASER and VTube-STEP
|
Follow these steps in Transfluid tProject to set up communications for VTube-LASER and VTube-STEP |
STEP 1: Enter Options Window
|
Click on the blue button wrench/screwdriver button in the upper right corner of the user interface. |
STEP 2: Enter the Import/Export Tab
|
Click on the Import/Export tab. |
STEP 3: Set the Import Box Settings
|
Enter the set up data in the Import box.
|
STEP 4: Check for a Green LED in the Main User Interface
|
Close the options menu with the OK button and check for the Supravision communications LED in the lower right corner of tProject. The LED should be green. |
How to Prepare tProject to Receive New Data from VTube
|
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. STEP 1: Clear the tProject ProjectSTEP 2: DO NOT Enter a Project NameThis allows VTube to control the new incoming name. STEP 3: Click on OK |
How to Send New Data to tProject from VTube-STEP
|
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. This allows a user to import a solid model of any tube, then send it to tProject. STEP 1: Import the ModelImport the part using standard VTube-STEP procedures STEP 2: Bender Output MenuClick on the Bender Output button in the navigation pane. STEP 3: Bender NumberSelect the bender number for the Transfluid bender. STEP 4: SendClick Send to Bender. VTube will show "Send to Bender Complete" if it was able to save the output data for Transfluid. |
STEP 5: tProject Will UpdatetProject will display the new part immediately. STEP 6: Save the tProject ProjectIt is important to save the new tProject project file using the disk button on the left. tProject does not automatically save the incoming data to disk. |
How to Prepare tProject for Bender Corrections from VTube-LASER
|
The Transfuild tProject program can receive correction data for an existing part from VTube-LASER. Follow these steps to set up tProject to receive corrections. Load an existing tProject ProjectThe project to correct must be loaded to tProject memory, and must also exist as a tProject .tfp file. (When tProject answers VTube-LASER requests for data, it always gives the data currently in the tfp file - not the data on the screen.) |
How to Correct tProject from VTube-LASER
|
The project must have a Part Number that is identical to the project file name in tProject. |
STEP 2: Enter the Bender Setup Menu
|
This menu allows you to communicate with any bender in the VTube-LASER network.
|
STEP 3: Bring Data Into This Window
|
If there is now data in the window like shown in the previous image, then click on "Copy the Master Part Setup Values into these fields" button.
|
STEP 4: Click on Correct the Bender
|
Find and click on the "Correct the Bender" button in the lower right corner.
|
STEP 5: RECALL Bender Data
|
Press the RECALL LRA from BENDER button.
|
|
|
The RECALL window with a timer will display.
|
Other Pages
- See VTube-LASER
- See VTube-STEP