This describes basic principles for automatically setting the pressure to LOW in CNC Bender.

Contents

 [hide

Modify the CONSTANT RUN Processlist

The Constant Run Processlist is good for tasks that should run ever 3/4 of a second. The process is reserved for non-motion type commands.

This is an example of watching for the high pressure output, and time beyond the last cycle:

[if] and, BeyondPowerOnTime=2000, BeyondLastCycleTime=5000, BeyondLastCycleTime=not(6000), output=Output_High_Pressure
  [display]AUTOMATIC HIGH to LOW PRESSURE After 5 Seconds 
  LowPressureOn
[end]

In the example above, the LowPressureOn command will run...

  • When master motor power has been on for at least 2 seconds
  • The high pressure output is ON.
  • And the processor has been idle for between 5 and 6 seconds.

The "and" keyword in the [if] statement means that ALL of these conditions in the parameter line must be true. If they are true, then the LowPressureOn command is called.


IDEA 3: Send New Data or Corrections Data From a Measuring Center Through Benderlink

Benderlink for CNC Bender is designed primarily as a way to connect CNC Bender to a measuring center to allow the measuring center to control the bender setup.

It is possible to connect to any SV-Network-compatible bender, or any Eaton-Leonard-Premier compatible bender with Benderlink.

See more here: Benderlink for CNC Bender



IDEA 4: Combine Ideas 1 and 2

You could use SVin in CNC Bender OFFLINE at a remote engineering station to use data from outside sources to setup the bender before the data reaches the operator station.