Difference between revisions of "VTube Communication for BLM VGP3D"
(→SIMULATE and RUN) |
(→SIMULATE and RUN) |
||
Line 240: | Line 240: | ||
* In the VGP3D software, press the measuring center icon again to be ready for communications from VTube-LASER in case another correction is needed.<br><br> | * In the VGP3D software, press the measuring center icon again to be ready for communications from VTube-LASER in case another correction is needed.<br><br> | ||
* Take the part back to VTube-LASER to measure it again for qualification. (Repeat from "Bend the Part on the BLM then Open Measuring Center Communications in VGP3D" above.) | * Take the part back to VTube-LASER to measure it again for qualification. (Repeat from "Bend the Part on the BLM then Open Measuring Center Communications in VGP3D" above.) | ||
+ | |||
+ | [[VTube_Communication_for_BLM_VGP3D#Bend_the_Part_on_the_BLM_then_Open_Measuring_Center_Communications_in_VGP3D]] | ||
</td> | </td> |
Revision as of 14:18, 14 July 2022
About this Page
This page describes the setup and use of the recommended BLM communications protocol for VTube. |
General Communications Setup at the BLM Bender for Both Protocols
|
PROTOCOL 1: BLM SVNET PROTOCOL (SW0453)
The BLM SVNET protocol is the PREFERRED PROTOCOL for CORRECTING the BLM. BLM SUPRAVISION NETWORK PROTOCOL - PreferredThis is the communications protocol that we recommend you use.
|
BLM SVNET PROTOCOL: Setup in VTube-LASER
Entering VTube-LASER Benderlink Setup
|
Setup the Benderlink Network Grid for the BLM SVNET Protocol
|
BLM SVNET PROTOCOL: How to SEND CORRECTION Data to the BLM Control from VTube-LASER
Bend the Part on the BLM then Open Measuring Center Communications in VGP3DClick on the measuring center image to the right of the part number.
|
Measure the tube with VTube-LASERMeasure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
|
Correct the BLM with VTube-LASER - Enter BENDER SETUP
Follow these steps in the VTube-LASER: Press the "BENDER SETUP button in the Navigation Pane. |
INITIAL RECALL Setup of Bender Setup Window
These steps assume that you have programmed a part into the bender and that you have measured and aligned a part. STEP 1 - Set the correct bender number at the top of the window. The BLM SVNET bender icon should display if you have already set up the bender protocol in the Benderlink grid.
|
RECALL Warning Boxes
VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.
|
THE BLUE COLUMNS SHOULD MATCH THE BLM XcYcZc DATA AFTER THE RECALL
After the RECALL, the blue columns should show the data that is programmed in the BLM control. |
SEND THE CORRECTIONS TO THE BLM FILE
SAVE the Correction data to the file for the BLM by pressing AUTO SEND BENDER CORRECTIONS.
|
AT THE BLM, Close the Communications Window
If you sent the correction data (the orange columns of data) from VTube-LASER to the BLM, then you can close the BLM communications window at the BLM and then check the new XYZc bender values. Be sure that they match the data in the orange cells in VTube. |
SIMULATE and RUN
|
IMPORTANT RULES for CORRECTIONS LOOPS
|
See also VTube Communication for BLM VGP3D - Alternative Protocols
Other Pages
- See VTube-LASER
- See VGP3D
- See BLM for information about BLM Group