Difference between revisions of "VTube Communications With Transfluid Benders"
Line 4: | Line 4: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | |||
As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER.<br><br> | As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER.<br><br> | ||
+ | This page describes the use of the VTube-LASER and VTube-STEP to Transfluid bender communications.<br><br> | ||
<br><br> | <br><br> | ||
Revision as of 00:57, 30 March 2021
As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER. |
Back to VTube-LASER
Configuring VTube-STEP and VTube-LASER for Communications with Transfluid tProject
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for Transfluid Supravision Network Protocol
|
Configuring Transfluid tProject for Communications with VTube-LASER and VTube-STEP
Follow these steps in Transfluid tProject to set up communications for VTube-LASER and VTube-STEP |
STEP 1: Enter Options Window
Click on the blue button wrench/screwdriver button in the upper right corner of the user interface. |
STEP 2: Enter the Import/Export Tab
Click on the Import/Export tab. |
STEP 3: Set the Import Box Settings
Enter the set up data in the Import box.
|
STEP 4: Check for a Green LED in the Main User Interface
Close the options menu with the OK button and check for the Supravision communications LED in the lower right corner of tProject. The LED should be green. |
How to Prepare tProject to Receive New Data from VTube
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. STEP 1: Clear the tProject ProjectSTEP 2: DO NOT Enter a Project NameThis allows VTube to control the new incoming name. STEP 3: Click on OK |
How to Send New Data to tProject from VTube-STEP
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. This allows a user to import a solid model of any tube, then send it to tProject. STEP 1: Import the ModelImport the part using standard VTube-STEP procedures STEP 2: Bender Output MenuClick on the Bender Output button in the navigation pane. STEP 3: Bender NumberSelect the bender number for the Transfluid bender. STEP 4: SendClick Send to Bender. VTube will show "Send to Bender Complete" if it was able to save the output data for Transfluid. |
STEP 5: tProject Will UpdatetProject will display the new part immediately. STEP 6: Save the tProject ProjectIt is important to save the new tProject project file using the disk button on the left. tProject does not automatically save the incoming data to disk. |
How to Prepare tProject for Bender Corrections from VTube-LASER
The Transfuild tProject program can receive correction data for an existing part from VTube-LASER. Follow these steps to set up tProject to receive corrections. Load an existing tProject ProjectThe project to correct must be loaded to tProject memory, and must also exist as a tProject .tfp file. (When tProject answers VTube-LASER requests for data, it always gives the data currently in the tfp file - not the data on the screen.) |
How to Set Up the VTube-LASER Project for Bender Corrections to tProject
The project must have a Part Number that is identical to the project file name in tProject. |
STEP 2: Enter the Bender Setup Menu
This menu allows you to communicate with any bender in the VTube-LASER network.
|
STEP 3: Bring Data Into This Window
If there is now data in the window like shown in the previous image, then click on "Copy the Master Part Setup Values into these fields" button.
|
STEP 4: Click on Correct the Bender
Find and click on the "Correct the Bender" button in the lower right corner.
|
STEP 5: RECALL Bender Data
Press the RECALL LRA from BENDER button.
|
|
The RECALL window with a timer will display. Allow tProject to answer VTube-LASER.
|
STEP 6: Allow VTube-LASER to Configure
If the incoming bend count does not match what is currently in VTube-LASER, then VTube-LASER will ask you for some decisions like this one. Just Press "USE..." to let the incoming data takeover the page.
|
STEP 7: Bender Setup is Complete
The Bender Setup window is completely ready. This setup will be stored with the project from this point on. Press "Close this Window", bend, measure, and align the tube in VTube-LASER, then come back into this Bender Setup menu if the part is not within tolerance.
|
How to Send Corrections tProject Data with VTube-LASER Bender Setup
During measurement, VTube-LASER will automatically create correction data that will be transferred to Bender Setup. |
STEP 2: Enter the Bender Setup Menu
The white columns will show Adjustments that can be applied to the bender. |
STEP 3: RECALL then SEND
To be sure that the Blue columns have the latest data as was programmed by the bender operator at the Transfluid, press the RECALL LRA from BENDER button. |
STEP 4: tProject Will Receive Data and Ask for Confirmation
tProject will receive the data immediately if the part number is correct. Since data is on the screen in tProject, it will ask for confirmation before allowing the data to import. |
STEP 5: SAVE the tProject Project File
Press the SAVE disk to save the tProject changes.
|
tProject Rules
Here are important rules for tProject communication.
Rule 1 - Conversion of Linear Data
tProject will always convert and handle data in the linear unit that is being displayed on the screen. |
Rule 2 - tProject Will Block the Wrong Part
Unless the project is cleared without a part name, tProject will always block any data it receives that has the wrong VTube-LASER part number. |
Rule 3 - Disk File Recall
tProject always answers VTube-LASER RECALLS with the project data in the disk file - NOT the project data on the screen. |
Rule 4 - tProject Does Not Answer A VTube-LASER Recall
If tProject does not answer a VTube-LASER RECALL when everything else is working, then that tProject project does not exist. |
Rule 5 - tProject Project Save After Receive
It is important to manually save the data that was just received by tProject from VTube-LASER. tProject will not save it automatically. |
Other Pages
- See VTube-LASER
- See VTube-STEP