Difference between revisions of "VTube Communications With Transfluid Benders"
(→How to Send New Data to tProject from VTube-STEP) |
(→How to Send New Data to tProject from VTube-STEP) |
||
| Line 175: | Line 175: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
| − | [[image:VTube-STEP_TransfluildSend.png|700px]] | + | [[image:VTube-STEP_TransfluildSend.png|700px]]<br><br> |
| + | [[image:Transfluid_ReceivedNewData.png|700px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Revision as of 20:55, 29 March 2021
|
This page describes the use of the VTube-LASER to Transfluid bender corrections. |
Back to VTube-LASER
Contents |
CONFIGURING VTUBE-STEP AND VTUBE-LASER for COMMUNICATIONS with TRANSFLUID tPROJECT
As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER.
You can set this protocol in the Benderlink setup grid in System Options.
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for Transfluid Supravision Network Protocol
|
CONFIGURING TRANSFLUID TPROJECT FOR COMMUNICATIONS WITH VTUBE-LASER AND VTUBE-STEP
|
Follow these steps in Transfluid tProject to set up communications for VTube-LASER and VTube-STEP |
tProject Configuration STEPS
STEP 1: Enter Options Window
|
Click on the blue button wrench/screwdriver button in the upper right corner of the user interface. |
STEP 2: Enter the Import/Export Tab
|
Click on the Import/Export tab. |
STEP 3: Set the Import Box Settings
|
Enter the set up data in the Import box.
|
STEP 4: Check for a Green LED in the Main User Interface
|
Close the options menu with the OK button and check for the Supravision communications LED in the lower right corner of tProject. The LED should be green. |
How to Prepare tProject to Receive New Data from VTube
|
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. STEP 1: Clear the tProject ProjectSTEP 2: DO NOT Enter a Project NameThis allows VTube to control the new incoming name. STEP 3: Click on OK |
How to Send New Data to tProject from VTube-STEP
|
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. This allows a user to import a solid model of any tube, then send it to tProject. STEP 1: Import the ModelImport the part using standard VTube-STEP procedures STEP 2: Bender Output MenuClick on the Bender Output button in the navigation pane. STEP 3: Bender NumberSelect the bender number for the Transfluid bender. STEP 4: SendClick Send to Bender. |
Other Pages
- See VTube-LASER
- See VTube-STEP
