Difference between revisions of "Benderlink for MiiC 5.1"
From ATTWiki
(→25px NEW: Eaton Leonard Laservision Communication) |
|||
| (17 intermediate revisions by one user not shown) | |||
| Line 5: | Line 5: | ||
Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer.<br> | Connect to MiiC Benders, edit data, send solid models, save the MiiC data to your computer.<br> | ||
| − | ==Version 5== | + | ==Version 5.1== |
Release Date: October 6, 2014<br><br> | Release Date: October 6, 2014<br><br> | ||
* Back to [[Benderlink for MiiC Version Updates]] web page<br><br> | * Back to [[Benderlink for MiiC Version Updates]] web page<br><br> | ||
| Line 24: | Line 24: | ||
<td width=300 > | <td width=300 > | ||
[[image:vtube-step_logo.jpg|300px]]<br><br> | [[image:vtube-step_logo.jpg|300px]]<br><br> | ||
| − | The included VTube-STEP is upgraded to version 1.95. This allows you to import solid models into MiiC benders. See [[VTube-STEP]]<br><br> | + | The included VTube-STEP is upgraded to version 1.95. This allows you to import solid models into MiiC benders.<br><br> |
| + | * See [[VTube-STEP Revisions]] for details on new versions.<br><br> | ||
</td> | </td> | ||
<td> | <td> | ||
| Line 46: | Line 47: | ||
<br><br> | <br><br> | ||
| − | ==[[image:Check.jpg|25px]] | + | ==[[image:Check.jpg|25px]] ENHANCED - Improved Error Handling and Dialogs == |
| − | <table> | + | |
| − | <tr> | + | <table cellpadding=20> |
| − | <td | + | <tr valign=top> |
| − | The | + | <td width=300> |
| − | [[image: | + | The error dialogs and logging are new in this version.<br><br> |
| + | The ability to capture errors in Benderlink has been improved with this new logging system.<br><br> | ||
| + | Error logs can now be reported directly to the Advanced Tubular bug logging database through the internet.<br><br> | ||
| + | We've also included a new log viewer for viewing the error logs stored in the Benderlink configuration folder.<br><br> | ||
| + | [[image:eurekalog_benderlink_miic_5.1.png|300px]] | ||
| + | </td> | ||
| + | <td> | ||
| + | [[image:benderlink_miic_5.1_eurekalog_dialog1.png|400px]]<br><br> | ||
| + | [[image:benderlink_miic_5.1_eurekalog_dialog2.png|400px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
| − | |||
| − | |||
==[[image:Check.jpg|25px]] Other Changes== | ==[[image:Check.jpg|25px]] Other Changes== | ||
| Line 63: | Line 70: | ||
<tr> | <tr> | ||
<td width=400> | <td width=400> | ||
| − | * | + | *PRB Menu: The reverse calculate from PRB to XYZ feature is removed. It is a feature that has no-known value to customers.<br><br> |
| − | + | *New: MOXA serial device drivers are added since we now supply MOXA as our first choice of serial device servers.<br><br> | |
| − | + | ||
| − | + | ||
| − | *New: | + | |
</td> | </td> | ||
</tr> | </tr> | ||
Latest revision as of 17:04, 5 June 2017
|
Version 5.1Release Date: October 6, 2014
|
UPDATE: VTube-STEP 1.95
|
|
FIX: Rotation Calculation in MiiC Edit Part Data
|
Previous versions calculated the correct rotations - but inserted them in the wrong rows in the PRB data. |
ENHANCED - Improved Error Handling and Dialogs
Other Changes
|
Other Pages
- Back to Benderlink for MiiC Version Updates web page