Difference between revisions of "VTube Communications With Transfluid Benders"
(→Standard Network Connection) |
(→Standard Network Connection) |
||
Line 20: | Line 20: | ||
<tr> | <tr> | ||
<td width=300> | <td width=300> | ||
− | The connection to a Transfluid bender is | + | *The VTube-LASER connection to a Transfluid bender is a connection to the Transfluid tProject software.<br><br> |
+ | *The connection is through a simple LAN that shares a read/write location anywhere on the network.<br><br> | ||
+ | *It uses the principles of Supravision network protocol. VTube-LASER has a "Transfluid SVNET" protocol designed for this connection. | ||
</td> | </td> | ||
<td width=700> | <td width=700> |
Revision as of 17:03, 1 April 2021
As of version 3.0 build 456 (March 29, 2021), we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER. |
Standard Network Connection
|
Video
Video 20210330: VTube-LASER to Transfluid Bender Communications
This video shows how easy it is to communicate with Transfluid tProject bender software. |
Configuring VTube-STEP and VTube-LASER for Communications with Transfluid tProject
You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.
STEP 1: Enter the SYSTEM OPTIONS Menu in VTube
|
STEP 2: Setup the Benderlink Network Grid for Transfluid Supravision Network Protocol
|
Configuring Transfluid tProject for Communications with VTube-LASER and VTube-STEP
|
STEP 1: Enter Options Window
Click on the blue button wrench/screwdriver button in the upper right corner of the user interface. |
STEP 2: Enter the Import/Export Tab
Click on the Import/Export tab. |
STEP 3: Set the Import Box Settings
Enter the set up data in the Import box.
|
STEP 4: Check for a Green LED in the Main User Interface
Close the options menu with the OK button and check for the Supravision communications LED in the lower right corner of tProject. The LED should be green. |
How to Prepare tProject to Receive New Data from VTube
How to Send New Data to tProject from VTube-STEP
The Transfuild tProject program can receive data for a part that has never been sent to it before from VTube-STEP. This allows a user to import a solid model of any tube, then send it to tProject. STEP 1: Import the ModelImport the part using standard VTube-STEP procedures STEP 2: Bender Output MenuClick on the Bender Output button in the navigation pane. STEP 3: Bender NumberSelect the bender number for the Transfluid bender. STEP 4: SendClick Send to Bender. VTube will show "Send to Bender Complete" if it was able to save the output data for Transfluid. |
How to Prepare tProject for Bender Corrections from VTube-LASER
How to Set Up the VTube-LASER Project for Bender Corrections to tProject
The project must have a Part Number that is identical to the project file name in tProject. |
STEP 2: Enter the Bender Setup Menu
This menu allows you to communicate with any bender in the VTube-LASER network.
|
STEP 3: Bring Data Into This Window
If there is now data in the window like shown in the previous image, then click on "Copy the Master Part Setup Values into these fields" button.
|
STEP 4: Click on Correct the Bender
Find and click on the "Correct the Bender" button in the lower right corner.
|
STEP 5: RECALL Bender Data
Press the RECALL LRA from BENDER button.
|
|
The RECALL window with a timer will display. Allow tProject to answer VTube-LASER.
|
STEP 6: Allow VTube-LASER to Configure
If the incoming bend count does not match what is currently in VTube-LASER, then VTube-LASER will ask you for some decisions like this one. Just Press "USE..." to let the incoming data takeover the page.
|
STEP 7: Bender Setup is Complete
The Bender Setup window is completely ready. This setup will be stored with the project from this point on. Press "Close this Window", bend, measure, and align the tube in VTube-LASER, then come back into this Bender Setup menu if the part is not within tolerance.
|
How to Send Corrections tProject Data with VTube-LASER Bender Setup
During measurement, VTube-LASER will automatically create correction data that will be transferred to Bender Setup. |
STEP 2: Enter the Bender Setup Menu
The white columns will show Adjustments that can be applied to the bender. |
STEP 3: RECALL then SEND
To be sure that the Blue columns have the latest data as was programmed by the bender operator at the Transfluid, press the RECALL LRA from BENDER button. |
STEP 4: tProject Will Receive Data and Ask for Confirmation
STEP 5: SAVE the tProject Project File
Rules for tProject Communication
Here are helpful rules for tProject communication.
Rule 1 - tProject Automatically Converts Linear Units
tProject will always automatically convert the incoming data to the linear unit that is being displayed on the screen. |
Rule 2 - tProject Will Block the Wrong Part
Unless the project is cleared without a part name, tProject will always block any data it receives that has the wrong VTube-LASER part number. |
Rule 3 - tProject Answers Recalls with the Data in tProject Files
tProject always answers VTube-LASER RECALLS with the project data in the disk file - NOT the project data on the screen. |
Rule 4 - tProject Does Not Answer A VTube-LASER Recall When the Part Does Not Exist
If tProject does not answer a VTube-LASER RECALL when everything else is working, then that tProject project does not exist. In that case, the process will time-out. |
Rule 5 - Manually Save tProject Project Files After Receiving Data from VTube-LASER
It is important to manually save the data that was just received by tProject from VTube-LASER. tProject will not save it automatically. |
Other Pages
- See VTube-LASER
- See VTube-STEP