Difference between revisions of "VTube OMCG Bender Correction"
From ATTWiki
(→CORRECTIONS) |
(→Using the Measuring System Interface) |
||
| Line 32: | Line 32: | ||
| − | =Using the Measuring System Interface= | + | =Using the OMCG Measuring System Interface= |
<table width=1000> | <table width=1000> | ||
<tr valign=top> | <tr valign=top> | ||
| Line 59: | Line 59: | ||
<td width=300> | <td width=300> | ||
[[image:OMCGScreen_MeasuringSystemInterface_Window.png|700px]] | [[image:OMCGScreen_MeasuringSystemInterface_Window.png|700px]] | ||
| + | </td> | ||
| + | </tr> | ||
| + | </table> | ||
| + | |||
| + | |||
| + | |||
| + | =Configuring the OMCG Measuring System Interface= | ||
| + | <table width=1000> | ||
| + | <tr valign=top> | ||
| + | <td width=300> | ||
| + | Click on the setup button in the Measuring System Interface menu to configure the measuring center communications.<br><br> | ||
| + | |||
| + | ===Settings=== | ||
| + | * Bender Name: This is mnemonic. It is to help you know which bender is associated with the bender number.<br><br> | ||
| + | * Bender Number: The Supravision network protocol requires that every bend have a unique number if the benders are sharing the same network path for communications.<br><br> | ||
| + | * Paths: These are the paths used for VTube-LASER to communicate with the OMCG software. | ||
| + | * Timeouts: These are timeouts that allow the OMCG to know when it has waited too long for data to move in either direction. | ||
| + | * Radius Adjust Enable: This allows VTube-LASER to change the radius values with nominal and corrections communications. | ||
| + | * Allow negative angle: Wire benders can bend left or right depending on the sign of the bend angle. It is normal to make this feature active. | ||
| + | |||
| + | </td> | ||
| + | <td width=300> | ||
| + | [[image:OMCGScreen_MeasuringSystemInterface_Configuration_Window.png|700px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Revision as of 18:46, 14 February 2019
|
This page describes the use of the VTube-LASER to OMCG bender corrections. |
Back to VTube-LASER
Contents |
OMCG Communications Protocol
|
We worked with OMCG to add the Supravision Network protocol to their bender control software. This protocol is embedded in VTube-LASER. |
Using the OMCG Measuring System Interface
|
Click on the Measuring System button in the toolbar to load the Measure System Interface. NOMINAL EXPORT
NOMINAL IMPORT
CORRECTIONS
|
Configuring the OMCG Measuring System Interface
|
Click on the setup button in the Measuring System Interface menu to configure the measuring center communications. Settings
|
Other Pages
- See VTube-LASER
- See VTube-STEP
