Difference between revisions of "VTube Communication with AMOB"
(→Synchronizing the VTube-LASER and AMOB Data Before Corrections) |
(→Other Pages) |
||
(5 intermediate revisions by one user not shown) | |||
Line 32: | Line 32: | ||
</table> | </table> | ||
− | ==Communications Setup at the | + | ==Communications Setup at the AMOB Bender== |
<table> | <table> | ||
<tr valign=top> | <tr valign=top> | ||
Line 64: | Line 64: | ||
</table> | </table> | ||
− | ===Setup the Benderlink Network Grid for the | + | ===Setup the Benderlink Network Grid for the AMOB Bender=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 235: | Line 235: | ||
<td width=300> | <td width=300> | ||
− | ===Import the Correction Data | + | ===Import the Correction Data at the AMOB Control=== |
Save the Correction data to the file for the AMOB to import. | Save the Correction data to the file for the AMOB to import. | ||
<br><br> | <br><br> | ||
Line 277: | Line 277: | ||
To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.<br><br> | To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.<br><br> | ||
− | The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually. | + | The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually.<br><br> |
+ | |||
+ | The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part. | ||
</td> | </td> | ||
<td width=400> | <td width=400> | ||
Line 289: | Line 291: | ||
* See [[VTube-LASER]] | * See [[VTube-LASER]] | ||
* See [[VTube-STEP]] | * See [[VTube-STEP]] | ||
− | |||
− |
Latest revision as of 17:55, 24 January 2017
About this Page
This page describes the setup and use of the VTube to AMOB communications. |
The Basics of How It Works
|
Communications Setup at the AMOB Bender
|
Setup Benderlink at VTube-STEP or VTube-LASER
Entering Benderlink Setup
|
Setup the Benderlink Network Grid for the AMOB Bender
|
How to SEND MASTER BENDER Data to the AMOB Control from VTube-STEP
You can import data into VTube-STEP then send the bender data calculated to the AMOB bender using the VTube Input/Export menu. |
At the VTube-STEP Main ScreenMove to the VTube-STEP computer and follow these steps to transfer the bender data to the AMOB.
|
At the AMOB Bender Data Export Window (inside VTube-STEP)Press the Export button to save a VTL file on the network at the shared path for the AMOB bender. |
How to SEND CORRECTION Data to the AMOB Control from VTube-LASER
After Bending the Tube
Bend a tube then measure it with VTube-LASER.
Measure the tube with VTube-LASERMeasure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
|
Correct the AMOB with VTube-LASER - Enter BENDER SETUPFollow these steps in the VTube-LASER: Press the "BENDER SETUP button in the Navigation Pane. |
INITIAL Setup of Bender Setup WindowThe first time in this window for a new part will require these steps before you can correct the AMOB bender. STEP 1 - Set the correct bender number at the top of the window. The AMOB bender should display if you have already setup the bender protocol in the Benderlink grid.
|
Check the BLUE COLUMN DataThe LRA blue column data is now filled with the MASTER LRA data. This data MUST match the X axis, Y axis, Z axis bender data at the bender - or the corrections will be incorrect.
|
Send the Corrections to the AMOB VTL FileSave the Correction data to the file for the AMOB to import.
|
Import the Correction Data at the AMOB ControlSave the Correction data to the file for the AMOB to import.
|
AMOB Control Bender Data UpdatedThe bender data will be updated with the new values. |
Synchronizing the VTube-LASER and AMOB Data Before Corrections
It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied. To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part. The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually. The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part. |
Other Pages
- See VTube-LASER
- See VTube-STEP